Accuracy class according to OIML R60 | | | (GP) | (GP) | (GP) |
---|
Maximum number of verification intervals | (nLC) | | n.a. | 3000 |
---|
Minimum load cell verification interval | (vmin ) | | n.a. | Emax /12 500 |
---|
Temperature effect on minimum dead load output | (TC0) | %*RO/10°C | ± 0.0400 | ± 0.0112 |
---|
Temperature effect on sensitivity | (TCRO) | %*RO/10°C | ± 0.0200 | ± 0.0100 |
---|
Combined error | | %*RO | ± 0.0500 | ± 0.0200 | ± 0.0180 |
---|
Non-linearity | | %*RO | ± 0.0400 | ± 0.0166 | ± 0.0166 |
---|
Hysteresis | | %*RO | ± 0.0400 | ± 0.0166 | ± 0.0083 |
---|
Creep error (30 minutes) / DR | | %*RO | ± 0.0600 | ± 0.0166 | ± 0.0083 |
---|
Option Min. load cell verification interval | (vmin opt) | | n.a. | Emax /20 000; 250 kg or higher: Emax /25 000 |
---|
Option Temp. effect on min. dead load output | (TC0 opt) | %*RO/10° C | n.a. | ± 0.0070; 250 kg or higher: ± 0.0056 |
---|
Rated Output | (RO) | mV/V | 2 ± 5% |
---|
Zero balance | | %*RO | ± 5 |
---|
Excitation voltage | | V | 5…15 |
---|
Input resistance | (RLC) | Ohm | 1 100 ± 50 |
---|
Output resistance | (Rout) | Ohm | 960 ± 50 |
---|
Insulation resistance (100 V DC) | | MΩ | >5000 |
---|
Safe load limit | (Elim) | %*Emax | 200 |
---|
Ultimate load | | %*Emax | 300 |
---|
Safe side load | | %*Emax | 100 |
---|
Maximum platform size; loading acc. to OIML R76 | | mm | 600 x 600 for 50 kg / 800 x 800 for 100…500 kg / 1 000 x 1 000 for 1 000 kg |
---|
Maximum off centre distance at maximum capacity | | mm | 200 for 50 kg / 250 for 100…500 kg / 300 for 1 000 kg |
---|
Compensated temperature range | | ° C | .10…+40 |
---|
Operating temperature range | | ° C | .40…+80 (ATEX .40…+60) |
---|
Load cell material | | | stainless steel 17-4 PH (1.4548) |
---|
Sealing | | | complete hermetic sealing; cable entry sealed by glass to metal header |
---|
Protection according EN 60 529 | | | IP68 (up to 2 m water depth) / IP69K |
---|